Rockwell Automation 7000 PowerFlex Medium Voltage AC Drive (B Frame) - Classic Control User Manual

Page 471

Advertising
background image

Troubleshooting

7-49

7000 “B” Frame

7000-UM150I-EN-P – June 2013

WARNING

MESSAGE

WARNING

CODE

DESCRIPTION

RECOMMENDED ACTIONS

2U1A Device Wrn

264

PWM RECTIFIER SGCT WARNING

FOR REDUNDANT DEVICE CAPABILITY
ONLY

This warning will occur during the initial
contactor closure, the diagnostic sequence

after a start command, or the diagnostic
sequence after a stop command. The
rectifier monitors the state of the feedback

before a gate pulse is given, and monitors
the feedback after a gate pulse has been
sent. The SGCT has smart diagnostics, so

the feedback may indicate short before
firing, and if the pulse is received and the

device is really shorted, the diagnostic will
toggle the feedback to let you know the
problem is with the device, or the power

supply for that device.

The firmware now completes a diagnostics
sequence immediately after any drive reset,
with the goal of detecting warnings before
any destructive action is taken from the next
action. The main example of this is closing
the input contactor on a shorted bridge.

– Complete a resistance check per the

instructions in the manual

– NOTE: SGCTs may not have completely

shorted, and still could read in the kΩ

range – Any devices with low suspect
readings should be changed

– Check the LED status of the SCGT gate

driver card for abnormal readings

– Complete a Gating Test mode check on

the devices

– Verify the associated 20V power supply

is powered and active

– Verify all the power connections to the

SCGT firing card are seated properly

– NOTE: There is only the Redundant

option available on the Rectifier, and

only on 6P drives (SCR orPWM). You
can not have N-1 operation on the
rectifier since we can not control the line
voltage.

2U1B Device Wrn

270

2U1C Device Wrn

282

2U4A Device Wrn

267

2U4B Device Wrn

273

2U4C Device Wrn

285

2V3A Device Wrn

266

2V3B Device Wrn

272

2V3C Device Wrn

284

2V6A Device Wrn

269

2V6B Device Wrn

275

2V6C Device Wrn

287

2W2A Device Wrn

265

2W2B Device Wrn

271

2W2C Device Wrn

283

2W5A Device Wrn

268

2W5B Device Wrn

274

2W5C Device Wrn

286

2U1A Online Wrn

252

PWM RECTIFIER SGCT WARNING

FOR REDUNDANT DEVICES CAPABILITY
ONLY

This warning will occur during operation of

the drive. The drive has detected that the
feedback from the device was not correct,
and does not wait to determine the exact

problem. The drive polls the entire bridge 3
times before and 3 times after each gating
command. All 6 of these readings for each

device must be consistent for the warning to
occur. There is also a parameter called

Rectifier Device Diagnostic Delay (P266),
which allows you to change the number of
consecutive firings to eliminate nuisance

warnings. It will still poll 3 times before and
after each firing, but will now require the
condition to exist for the number of

consecutive firings set in the Diagnostic
Delay parameter for a warning to occur.

The firmware now completes a diagnostics
sequence immediately after any drive reset,

with the goal of detecting warnings before
any destructive action is taken from the next
action

– Complete a resistance check per the

instructions in the manual

– NOTE: SGCTs may not have completely

shorted, and still could read in the kΩ
range – Any devices with low suspect

readings should be changed

– Check the LED status of the SCGT gate

driver card for abnormal readings

– Complete a Gating Test mode check on

the devices

– Verify the associated 20V power supply

is powered and active

– Verify all the power connections to the

SCGT firing card are seated properly

– Reset the drive and let the offline

diagnostics further define the problem

– For nuisance faults, contact the factory

about extending the Diagnostic Delay

– NOTE: There is only the Redundant

option available on the Rectifier, and
only on 6P drives (SCR orPWM). You
can not have N-1 operation on the
rectifier since we can not control the line
voltage.

2U1B Online Wrn

258

2U1C Online Wrn

276

2U4A Online Wrn

255

2U4B Online Wrn

261

2U4C Online Wrn

279

2V3A Online Wrn

254

2V3B Online Wrn

260

2V3C Online Wrn

278

2V6A Online Wrn

257

2V6B Online Wrn

263

2V6C Online Wrn

281

2W2A Online Wrn

253

2W2B Online Wrn

259

2W2C Online Wrn

277

2W5A Online Wrn

256

2W5B Online Wrn

262

2W5C Online Wrn

280

Advertising