7. Enter the parameter linear number (in our example we have
entered 569) and then press Enter key. Once you press the Enter
key, the parameter description will appears on the screen as
shown in the picture below.
8. Press Enter key again. The display will change to the
„Diagnostics Setup‟ screen and the desired parameter gets
assigned to Trace 1. Now, press the down arrow key to move the
cursor to Trace 2 and repeat steps 3 – 8 above to assign a
parameter to Trace 2.
9. Repeat above steps until you have assigned the desired
parameters to all the traces from Trace1 to Trace8.
10. Now press F9 [TRIGGER] key. The first letter in the second line
on the screen will toggle between C and S. The letter C stands
for Continuous and S stands for Single shot. Select S for single
shot.