Programming Reference

4-17

In selections 5, 6, and 7, a digital input will initiate the selected preset speed which will

override the analog speed reference. Refer to table 4.4 in the P.031 parameter

description.

The selection is dependent upon what is selected for parameter P.007 (Terminal Strip

Digital Inputs Configure). The selection made in P.007 determines what the remaining

free digital inputs are used for. See table 4.3 for acceptable combinations.

P.008 Terminal Strip Speed Reference Source

This parameter

selects the source of

the terminal strip

speed reference.

The terminal strip

speed reference is

used when:

the terminal strip is
the selected control

source (P.000 = rE)

or

the local keypad or
serial port is the

selected control

source (P.000 =

LOCL or SErL) and

AUTO is selected

(AUTO LED is on).

Parameter Range:

0 = Analog reference. (Digital inputs 6, 7, and 8 are

not used. See P.007.)

1 = MOP selection. (Uses terminal strip digital input

6 for MOP increment and digital input 7 for the

MOP decrement function. Digital input 8 is not

used.)

2 = Two (2) preset speeds. (Uses terminal strip

digital input 6. Digital inputs 7 and 8 are not

used.)

3 = Four (4) preset speeds. (Uses terminal strip

digital inputs 6 and 7. Digital input 8 is not used.)

4 = Eight (8) preset speeds. (Uses all terminal strip

digital inputs.)

5 = Analog reference and one (1) preset speed.

(Uses terminal strip digital input 6. Digital inputs

7 and 8 are not used.)

6 = Analog reference and three (3) preset speeds.

(Uses terminal strip digital inputs 6 and 7. Digital

input 8 is not used.)

7 = Analog reference and seven (7) preset speeds.

(Uses terminal strip digital inputs 6, 7, and 8.)

Default Setting:

0

Parameter Type:

Configurable

Refer also to parameters:

P.007 Terminal Strip Digital Inputs Configure

P.031 Preset Speed 1

r.030 Digital Input Configuration