Xl – Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 55

Advertising
background image

Starting Up the Drive for Vector Regulation

2-17

Step 6.8 Press the ENTER key to display the default setting of U.001.

This displays the default setting for Encoder

PPR, 1024 PPR.

Step. 6.9 Press the ▲

key to increase the PPR, or the ▼ key to decrease the PPR.

Select one of the four PPR values if an

encoder is used. Select SE if an encoder is

not used. See the description of U.001 in

chapter 4 for more information.

VALUE ENTERED:

Step 6.10 Press the ENTER key to save the changed value.

After pressing ENTER, the same parameter

is displayed. You can now move to the next

parameter.

!

ATTENTION: Do not use a 4096 PPR encoder with a 2-pole motor.

Overspeed and motor damage can result. Failure to observe this

precaution could result in bodily injury.