Monitor mode leds, 7 monitor mode leds – Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 85

Advertising
background image

Using the Keypad/Display to Program, Monitor, and Control the Drive

3-9

3.7 Monitor Mode LEDs

Table 3.3 describes the values that will be displayed when the corresponding monitor

mode LED is on.

Table 3.3 – Monitor Mode LEDs

Monitor Mode LED

Corresponding Display When LED Is On (Actual Values)

SPEED

Motor speed is displayed. This value is scaled in parameter

P.028.

VOLTS

Drive output volts are displayed. This value is not DC bus

volts.

AMPS

Drive output amps are displayed.

Hz

Drive output frequency in hertz is displayed.

Kw

Output power of the drive in kilowatts is displayed. Note that

this is intended for display purposes as a general indication

of kilowatt output and should not be used for control or exact

metering purposes.

TORQUE

Motor output torque is displayed in percent. (Valid only for

vector regulation).

ALL LEDs

Selected speed reference (in P.028 units) or torque

reference (in %) is displayed.

Advertising