Programming Reference

4-21

Selections 2 and 3 select the same signals as selections 0 and 1, but instead of

providing a 5 V (1/2 scale) offset to allow for a bipolar signal, no 5 V offset is used.

Instead, the signal is presented in a unipolar manner. The absolute value of the

selected signal is used to drive the analog output over its full range of 0 to 10VDC.

This provides greater resolution of the selected signal at the expense of indicating

polarity. Refer to figure 4.2.

Note that in V/Hz control, signals are updated every 500 ms. In Vector control, all

signals are updated every 5.0 ms.

P.012 Terminal Strip Analog Output Source

This parameter

selects the source of

the analog output

signal.

Parameter Range:

0 = Speed (bipolar)

1 = Torque (bipolar)

2 = Speed (unipolar)

3 = Current (unipolar) (V/Hz)

Torque (unipolar) (vector)

Default Setting:

0

Parameter Type:

Tunable

Refer also to parameters:

N/A

Figure 4.2 – Analog Output Selection and Scaling

 9

 P$

 9

 P$