U.048 outer control loop proportional trim enable – Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 176

Advertising
background image

4-90

GV3000/SE AC Drive Software Reference, Version 6.06

If U.048 = ON, a gain block scales the outer control loop output proportional to the

speed reference signal at the output of the S/Ramp block (normalized to top speed).

See figure 4.15. See Appendix H for the complete outer control loop block diagram.

This parameter limits the control the outer control loop has on the speed reference

during line start.

U.048 Outer Control Loop Proportional Trim Enable

This parameter

enables the gain

block on the output of

the outer control loop

PI block.

Parameter Range:

OFF = Disable proportional trim
ON = Enable proportional trim

Default Setting:

OFF

Parameter Type:

Configurable

Refer also to parameters:

U.040 Outer Control Loop Feedback Source

U.041 Outer Control Loop Lead/Lag Select

U.042 Outer Control Loop Lead/Lag Low Frequency

U.043 Outer Control Loop Lead/Lag Ratio

U.044 Outer Control Loop Reference Gain

U.045 Outer Control Loop Proportional Gain

U.046 Outer Control Loop Integral Gain

U.047 Outer Control Loop Trim Range Percentage

Figure 4.15 – Outer Control Loop Proportional Trim