Sl – Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 47

Advertising
background image

Starting Up the Drive for Vector Regulation

2-9

Step 5.4 Press the ENTER key to display the default setting of P.001.

This displays the default setting for

acceleration time (20.0 seconds).

Step 5.5 Press the ▲

key to increase acceleration time, or the ▼ key to decrease

acceleration time.

The adjustment range is:

0.1 to 999.9 seconds.

VALUE ENTERED:

Step 5.6 Press the ENTER key to save the changed value.

After pressing ENTER, the same

parameter number is displayed. You can

now go to the next parameter.

Step 5.7 Press the ▲

key to display P.002, Decel Time 1 (RAMP 1).

This parameter sets the deceleration

time in seconds. The default stop

method is coast-to-stop, set in P.025.