P.027 forward/reverse configuration, P.028 speed display scaling – Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 117

Advertising
background image

Programming Reference

4-31

When P.027 is set to 0, the forward/reverse input allows forward or reverse rotation of

the motor.

When P.027 is set to 1, reverse rotation of the motor is prohibited and the

forward/reverse selection from the front panel or serial port is set to forward. Note that

reverse rotation is prohibited regardless of the polarity of the speed reference input.

When P.027 is set to 2, the state of the forward/reverse input is latched when the

motor is started (RUNNING LED is on). Direction changes requested from any control

source after the motor is started are ignored. Note, however, that this selection will not

inhibit a motor direction change due to a change in the polarity of the speed reference

input.

In V/Hz or SVC regulation, setting H.016 (Sync Mode Direction) or U.031 (SVC Sync

Direction) to any value but F or OFF may cause the motor to operate in the reverse

direction briefly regardless of the setting in P.027.

For

vector regulation, P.028 will correspond to U.017:

Actual Speed in RPM x P.028 = value displayed when SPEED monitor mode or

U.017 selected reference is selected.

P.027 Forward/Reverse Configuration

This parameter

specifies how the

motor responds to

forward or reverse

inputs from any

control source.

Parameter Range:

0 = Forward or reverse enabled from the selected

control source

1 = Reverse disabled from the selected control

source

2 = The state of the forward/reverse input is latched

when the motor is started

Default Setting:

0

Parameter Type:

Tunable

Refer also to parameters:

N/A

P.028 Speed Display Scaling

This parameter

defines the scaling

value applied to the

manual reference,

the selected speed

reference, and the

output speed

displays.

Parameter Range:

10 to 9999

Default Setting:

Synchronous speed based on H.001 (assuming a

4-pole motor) (V/Hz)

U.017 (vector)

Parameter Type:

Tunable

Refer also to parameters:

U.017 Motor Top Speed

H.001 Motor Nameplate Base Frequency

Advertising