Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 58

Advertising
background image

2-20

GV3000/SE AC Drive Software Reference, Version 6.06

Step. 6.17 Press the ▲

key to increase the motor nameplate base frequency or the

key to decrease motor nameplate base frequency.

The adjustment range is:

15.0 Hz to 120.0 Hz

VALUE ENTERED:

Step 6.18 Press the ENTER key to save the changed value.

After pressing ENTER, the same parameter

is displayed. You can now move to the next

parameter.

Step 6.19 Press the ▲

key to display U.004, Motor Nameplate Amps.

This parameter is the Motor Nameplate

Rated Amps and is taken from the motor

nameplate.

X

)RUZDUG

5HYHUVH

$872

0$1

(17(5

581

-2*

PROGRAM

67$57

6723

5(6(7

63(('
92/76
$036
+]

.Z

72548(
3DVVZRUG

5811,1*

5(027(
-2*

$872
)25:$5'
5(9(56(
352*5$0

5(/,$1&(

(/(&75,&

!

ATTENTION: This parameter setting must not exceed the rated amps

found on the motor nameplate. Overcurrent or excess heating of the

motor could result if this is not the case. Failure to observe this precaution

could result in damage to, or destruction of, the equipment.