The avoided frequency range is:

(Avoidance freq. midpoint ‘n’ - freq. band ‘n’/2) < range < (avoidance freq. midpoint ‘n’ + freq. band ‘n’/2)

where n = 1, 2, or 3.

Note that when Forward/Reverse Configuration (P.027) is set to 1, setting this
parameter to r, Fr, or rF may still cause the motor to operate in the reverse direction.

H.011, H.013, and H.015 Avoidance Frequency Band 1, 2, and 3

This parameter

specifies the

avoidance frequency

band that will be

applied to each

avoidance frequency

midpoint selected in

H.010, H012, and

H.014.

Parameter Range:

0.2 to 10 Hz

Default Setting:

2.0

Parameter Type:

Tunable

Refer also to parameters:

H.009 Avoidance Frequency Enable

H.010, H.012, H.014 Avoidance Frequency Midpoint

1, 2, and 3

H.016 Sync Direction

When starting into a

rotating load is

required, this

parameter selects the

direction in which the

drive will search in

order to synchronize

to motor speed.

Parameter Range:

OFF = Disable synchronization
F = Search starts in motor forward direction
r = Search starts in motor reverse direction
Fr = Search starts in motor forward then reverse

direction

rF = Search starts in motor reverse then forward

direction

Default Setting:

OFF

Parameter Type:

Configurable

Refer also to parameters:

N/A

!

ATTENTION: When starting with search enabled, there will be a several

second delay, and the motor may drift in the forward and reverse direction,

before the motor begins operating in the desired direction even if reverse

has been disabled in P.027. Stay clear of rotating machinery. Failure to

observe this precaution could result in bodily injury.