Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 22

Advertising
background image

1-8

GV3000/SE AC Drive Software Reference, Version 6.06

Step 3.15 Press the ENTER key to display the default setting of P.004.

This shows that the default setting for

Maximum Speed is 60.0 Hz.

Step 3.16 Press the ▲

key to increase maximum speed or the ▼ key to decrease

maximum speed.

The adjustment range is:

15.0 Hz to the value set for H.022

(Overfrequency Limit).

The maximum value is 210 Hz.

VALUE ENTERED:

Step 3.17 Press the ENTER key to save the changed value.

After pressing ENTER, the same

parameter number is displayed. You can

now go to the next parameter.

!

ATTENTION: The user is responsible for ensuring that driven machinery,

all drive-train mechanisms, and application material are capable of safe

operation at the maximum operating speed of the drive. In V/Hz

regulation, overfrequency protection in the drive is provided by means

of H.022. Failure to observe this precaution could result in bodily injury.



)RUZDUG

5HYHUVH

$872

0$1

(17(5

581

-2*

PROGRAM

67$57

6723

5(6(7

63(('
92/76
$036
+]

.Z

72548(
3DVVZRUG

5811,1*

5(027(
-2*

$872
)25:$5'
5(9(56(
352*5$0

5(/,$1&(

(/(&75,&

S

)RUZDUG

5HYHUVH

$872

0$1

(17(5

581

-2*

PROGRAM

67$57

6723

5(6(7

63(('
92/76
$036
+]

.Z

72548(
3DVVZRUG

5811,1*

5(027(
-2*

$872
)25:$5'
5(9(56(
352*5$0

5(/,$1&(

(/(&75,&

Advertising