P.039 encoder loss enable – Rockwell Automation GV3000/SE AC Gen. Purpose and Vector Drive Software Start-Up and Ref. Manual User Manual

Page 121

Advertising
background image

Programming Reference

4-35

P.031 to P.038 Preset Speed 1 through Preset Speed 8

(continued)

The encoder loss detection diagnostic is functional only when the drive is operating as

a speed regulator (not as a torque regulator).

When the diagnostic is enabled and feedback from the encoder is not detected, a

drive fault will be logged (EL will be displayed).

If the encoder fails, loss will be detected down to 1 RPM. If only one of the quadrature

feedback wires is disconnected, loss may not be detected below 15 RPM.

Figure 4.6 – Typical Preset Operation

P.039 Encoder Loss Enable

This parameter

enables the encoder

loss detection

diagnostic.

This diagnostic is

available for flux

vector control (FVC)

only.

Parameter Range:

OFF = Disable encoder loss diagnostic
ON = Enable encoder loss diagnostic

Default Setting:

OFF

Parameter Type:

Tunable

Refer also to parameters:

N/A

&ORVHG

5XQ DQG 6WDUW

&ORVHG

&ORVHG

&ORVHG

&ORVHG

'LJLWDO ,Q 

7HUP 

&ORVHG

&ORVHG

'LJLWDO ,Q 

7HUP 

&ORVHG

'LJLWDO ,Q 

7HUP 

3

3UHVHW 

RU 76

$QDORJ LQ

3

3

3

3

3

3

3

Advertising