4-79

U.018 AC Line Volts

The phase-to-phase

line voltage provided

to the drive input

power terminals.

The value entered

should be within 10%

of actual line voltage.

Parameter Range:

300 to 565 VAC

Default Setting:

460

Parameter Type:

Configurable

Refer also to parameters:

N/A

U.019 Flux Current Regulator Proportional Gain

This parameter

determines the

performance of the

magnetizing current

regulator.

For most

applications, it is

recommended that

this parameter not be

changed.

Parameter Range:

0.10 to 31.99

Default Setting:

Power Module-dependent, see Appendix C

Parameter Type:

Tunable

Refer also to parameters:

U.020 Flux Current Regulator Integral Gain

U.020 Flux Current Regulator Integral Gain

This parameter

determines the

performance of the

magnetizing current

regulator.

For most

applications, it is

recommended that

this parameter not be

changed.

Parameter Range:

10.0 to 628.0 radians/second

Default Setting:

Power Module-dependent, see Appendix C

Parameter Type:

Tunable

Refer also to parameters:

U.019 Flux Current Regulator Proportional Gain