Figure 6-5 Response of check sum flag

@Example 4 <ND-6080>

User command:

$302<CR>

Response:

!30500600<CR>

!

Command is valid.

30 Address

ID.

50

Counter Input Mode.

06

Baud rate is 9600 bps.

00

checksum is disable, frequency gate is 0.1 second.

@Example 5 <ND-6531>

User command:

$302<CR>

Response:

!3040662103<CR>

!

Command is valid.

30 Address

ID.

40

Digital I/O module.

66

Baud rate is 9600 for RS-422/485 and RS-232.

2103 Addressable

mode

Checksum is disable
RS-485 interface
Append <CR>
Non-parity
8 data bit

Reserved
Must to be 0

Checksum
0 : disable
1 : enable

Reserved

Must to be

000

Module Type
000: ND-6050
001: ND-6060
010: ND-6052
011: ND-6053
100: ND-6058
101: ND-6063
110: ND-6054
111: ND-6056