ADLINK ND-6067 User Manual

Page 229

Advertising
background image

227

6.7.32 Read Digital Output and Alarm Status

@Description

Read the current digital output channel values and the status of
alarm function.

@Syntax

@(Addr)DI<CR>

@

Command leading code.

(Addr) Address

ID

DI

Read digital data output and alarm status command
code.

@Response

!(Addr)(AStatus)(DoData)00<CR>

or

?(Addr)<CR>

!

Command is valid.

?

Command is invalid.

(Addr) Address

ID.

(AStatus)

0: counter 0 alarm is disabled, counter 1 alarm is
disabled.
1: counter 0 alarm is enabled, counter 1 alarm is
disabled.
2: counter 0 alarm is disabled, counter 1 alarm is
enabled.
3: counter 0 alarm is enabled, counter 1 alarm is
enabled.

(DoData)

00: DO0 is OFF, DO1 is OFF
01: DO0 is ON, DO1 is OFF
02: DO0 is OFF, DO1 is ON
03: DO0 is ON, DO1 is ON

(6080)

Advertising
This manual is related to the following products: