6.7.21 Set TTL Input High Trigger Level
@Description
Set the TTL input high trigger level, for voltage level higher than this
value is recognized as logic high.
@Syntax
$(Addr)1H(ThData)<CR>
$
Command leading code.
(Addr)
Address ID (2-character)
1H
TTL input high trigger level command code.
(ThData)
The high trigger level for TTL input. The unit is 0.1 V
and its resolution is 0.1 V too. This value range from
0.1 to 5V, which is a 2-digit integer.
@Response
!(Addr)<CR>
or
?(Addr)<CR>
!
Command is valid.
?
Command is invalid.
(Addr) Address
ID.
@Example
User command:
$301H30<CR>
Response:
!30<CR>
Item Meaning
Description
$
(Leading Code)
Command leading code.
30
(Addr)
Address ID is 30H.
1H
Set TTL input high trigger level.
30 (ThData)
3
V
(6080)