Page 28

Advertising
background image

26

2.1.6 Setup

Objective of Setup

In normal condition, it is not necessary to setup the ND-6520. The default
configuration of this communication module is 9600 bps and data format of 8
data bits with 1 start bit, 1 stop bit, and no parity check. Note that the data format
is reserved to be compatible with other brand‘s communication port, it should not
be modified if only NuDAM is used in a system. The baud rate can be
configured according applications’ requirement.

Setup Equipments

Only screw driver is used to open the case. Software, power supply, and wiring
are not necessary.

Setup Procedure

Only hardware switch setting can be setup in ND-6520. The user can set the
speed of the serial interface ( RS-232 and RS-422

/RS-485 ), and the serial data

format. The speed and the data format on the whole RS-485 network must be
identical otherwise the communication will be not correct.

To setup the ND-6520, using the screw driver to open the case, then change the
switch setting. The new setting is valid after power on. The case must be put
back and locked carefully. Be careful not to scratch the surface of the circuit
while setting up, the surface coating or even the circuits will be damaged.

Default Setting

9600 baud rate

10 bits series data format : one start bit, eight data bits, one stop bit, no

parity check