ADLINK ND-6067 User Manual

Page 215

Advertising
background image

213

6.7.18 Read Minimum Input Signal Width at High Level

@Description

Read the minimum input signal width at high level.

@Syntax

$(Addr)0H<CR>

$

Command leading code.

(Addr)

Address ID (2-character)

0H

Set minimum input signal width at high level
command code.

@Response

!(Addr)(MinFData)<CR>

or

?(Addr)<CR>

!

Command is valid.

?

Command is invalid.

(Addr) Address

ID.

(MinFData)

The minimum width data at high level. The unit is

μs

and its resolution is 1

μs. This value range from 4 μs

to 1020

μs, which is a 4-digit integer.

@Example

User command:

$300H<CR>

Response:

!300100<CR>

Item Meaning

Description

$

(Leading Code)

Command leading code.

30

(Addr)

Address ID is 30H.

0H

Set minimum input signal width.

!

Command is valid.

30

Address of counter/frequency module.

0100

Digital filter value of minimum signal width at high
level is 100

μs.