6.7.24 Read TTL Input Low Trigger Level

@Description

Read the TTL input low trigger level.

@Syntax

$(Addr)1L<CR>

$

Command leading code.

(Addr)

Address ID (2-character)

1L

TTL input low trigger level command code.

@Response

!(Addr)(ThData)<CR>

or

?(Addr)<CR>

!

Command is valid.

?

Command is invalid.

(Addr) Address

ID.

(ThData)

The high trigger level for TTL input. The unit is 0.1 V
and its resolution is 0.1 V too. This value range from
0.1 to 5V, which is a 2-digit integer.

@Example

User command:

$301L<CR>

Response:

!3008<CR>

Item Meaning

Description

$

(Leading Code)

Command leading code.

30

(Addr)

Address ID is 30H.

1L

Read TTL input low trigger level.

!

Command is valid.

30

Address of counter/frequency module.

08

The low trigger level is 0.8 V.