5.5 Overview of NuDAM-6056

What is NuDAM-6056 ?

NuDAM-6056 provides 15 isolated digital output channels. All of the output
channels are common ground type and one of them is use the same pin with
default (use jumper to choose). The isolation voltage is up to 5000 Vrms. It
is suitable to use NuDAM-6056 in industrial environment with high voltage
electric shock.

5.5.1 Features of NuDAM-6056

z

15 bits digital open collector output with isolation protection and
common ground

z

5000 Vrms isolation voltage

z

Programmable host watchdog timer for host failure protection

z

Internal watchdog timer for device failure protection

z

Easy programming by software

z

Easy installation and wiring

5.5.2 Specifications of NuDAM-6056

‹ Interface

Interface : RS-485, 2 wires

Speed (bps) : 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K,

115.2K (115.2K is only for firmware reversion
above A4.00)

‹ Digital Output

Channel numbers : 15 isolation common ground output

channels(the fifteenth channel is the same with
default pin,but could use jumper to choose).

Output characteristic:open collector transistor

Maximum current sink:50mA(300mA for Hardware Reversion.A2)

Max.power dissiation:200mW(3W for Hardware Reversion.A2)

Isolation Voltage:5000Vrms

‹ Watchdog Function