6.7.2 Read Input Mode
@Description
Read the input signal mode of counter/frequency module.
@Syntax
$(Addr)B<CR>
$
Command leading code.
(Addr)
Address ID
B
Read input mode Command
@Response
!(Addr)(InType)<CR>
or
?(Addr)<CR>
!
Command is valid.
?
Command is invalid.
(Addr)
Address ID.
(InType)
0: TTL input mode.
1: Photo isolated input mode.
@Example
User command:
$30B<CR>
Response:
!301<CR>
!
Command is valid.
30
Address
1
Photo isolated input.
(6080)