FEXT Tr/Tf—Far-end crosstalk aggressor 20%-80% rise/fall time

Crosstalk dB Factor—This parameter, Y, defines how dB is calculated where dB = Y*log10(amplitude)

Compliance Mask—Select the channel compliance mask to be used in the channel analysis. The

Compliance Mask menu contains the following selections:
10GBASE-KR—Use the 10GBASE-KR channel compliance mask.

OIF CEI-28G-SR 3.0—Use the OIF CEI-28G-SR channel compliance mask.

OIF CEI-25G-LR 3.0—Use the OIF CEI-25G-LR channel compliance mask.

Custom—Refer to

Figure 2-93

. Several text boxes for each channel compliance check item are

shown. You can copy or manually input the mask definitions. The format for each mask definition

data point is “Frequency (in Hz)", followed by "Amplitude (in dB)”. The number of data points is

limited to the maximum text length allowed by the text box (the maximum size is 32767 bytes). The

frequency grid of a mask must be monotonic increasing.

Load from file—Allows you to load a predefined custom channel compliance. Each mask

definition starts with a keyword, followed by a pair of numbers that represent the data points for

“Frequency (Hz)" and "Amplitude (dB)”. Following is a sample of a custom channel compliance

mask file:

IL Mask Min
1 0
1e9 -1
10e9 -2.5
IL Mask Max
1 0
1e9 1
10e9 2.5
ILD Mask Min
1 0
1e9 -4
10e9 -4
ILD Mask Max
1 0
1e9 4
10e9 4
RL Mask
1 -10
1e9 -10
10e9 -4
ICR Mask
1e9 55
25e9 25
ICN Mask
1 10
5 10
25 0

When you click Plot, the Channel Viewer computes and generates a sequence of plots that show the

performance of the channels in the channel list
Insertion Loss Plot—This plot is labeled CP: IL. In this plot, the insertion loss of channels, fitted curve

of transmission channels’ insertion loss, crosstalk channels’ amplitude, and power sum of all crosstalk

channels is shown. An example is illustrated in the above figure.

Insertion Loss Deviation Plot—This plot is labeled CP: ILD. In this plot, the insertion loss deviation

is shown, as in the following figure.

2-114

Plot Configuration Panel

UG-1146

2015.05.04

Altera Corporation

Functional Description

Send Feedback

Advertising