Figure 2-98: 10GBASE-KR Channel Compliance Check User Interface

All parameters are predefined as described in the IEEE 802.3ap/10GBASE-KR standards, so there is no

user input. Click Plot to proceed. Channel Viewer computes and generates a sequence of plots that show

the performance of the channels in the channel list.
Insertion Loss Plot—This plot is labeled CP: IL. In this plot, the insertion loss of channels, fitted curve

of transmission channels’ insertion loss, maximum insertion loss limits, crosstalk channels’ amplitude,

and power sum of all crosstalk channels is shown. An example is illustrated in the above figure.

Insertion Loss Deviation Plot—This plot is labeled CP: ILD. In this plot, the insertion loss deviation

and ILD masks are shown, as in the following figure.

UG-1146

2015.05.04

Plot Configuration Panel

2-119

Functional Description

Altera Corporation

Send Feedback