Figure 2-98: 10GBASE-KR Channel Compliance Check User Interface
All parameters are predefined as described in the IEEE 802.3ap/10GBASE-KR standards, so there is no
user input. Click Plot to proceed. Channel Viewer computes and generates a sequence of plots that show
the performance of the channels in the channel list.
• Insertion Loss Plot—This plot is labeled CP: IL. In this plot, the insertion loss of channels, fitted curve
of transmission channels’ insertion loss, maximum insertion loss limits, crosstalk channels’ amplitude,
and power sum of all crosstalk channels is shown. An example is illustrated in the above figure.
• Insertion Loss Deviation Plot—This plot is labeled CP: ILD. In this plot, the insertion loss deviation
and ILD masks are shown, as in the following figure.
UG-1146
2015.05.04
Plot Configuration Panel
2-119
Functional Description
Altera Corporation