simulation results when no jitter or noise is present. JNEye automatically chooses the most suitable color

map based on the type or configuration of a simulation. The default color map is either Default or Blue.
• The Image Output menu allows you to generate output images in .png, .jpg, or .gif format. This is

useful when you want to generate images after simulation is done previously. (Refer to

Figure 2-77

.)

• When Save Selected Plot is clicked, a file browser helps you select the image file to be saved. An image

file of the currently selected plot is saved in the format specified in the Image Output.

• When Save All Plots is clicked, a folder browser helps you select the folder location where all image

files will be saved. Image files of all plots are saved in the format specified in the Image Output.

The JNEye Data Viewer Module shows the following types of simulation results:

Probability Density Function (PDF) Eye Diagram

This scope shows the PDF eye diagram (with probability color map), horizontal histogram at slicer

voltage level (fixed at 0 V in the JNEye), vertical histogram at Ideal Clock or CDR sampling phase, and eye

diagram opening width and height information. Device settings such as transmitter pre-emphasis/FIR

setting and receiver equalization settings are shown in the text display area below the plots.

UG-1146

2015.05.04

JNEye Data Viewer Module

2-83

Functional Description

Altera Corporation

Send Feedback