Supply Voltage

For supported devices, you can choose the supply voltage. In JNEye 15.0, the Arria 10 GX/SX/GT

transmitter model provides the following supply voltages:
Default-BP—Supply voltage for backplane applications that have a dependency on the data rate

setting

Default-C2C—Supply voltage for chip-to-chip applications that have a dependency on the data rate

setting

0.9 V (Arria 10 GX/SX/GT)

1.0 V (Arria 10 GX/SX/GT)

1.1 V (Arria 10 GT)

V

cm

V

cm

is the common voltage of the transmitted signal.

PVT

Select the process, voltage, and temperature (PVT) models for the selected transmitter device. PVT model

support varies depending on device type, device data availability, and model coverage. A message is

shown on the Transmitter tab page to indicate the PVT model coverage. Transmitter PVT model coverage

and conditions are shown in the following table.

Table 2-6: Transmitter PVT Model Coverage

Transmitter Type

Waveform PVT Model

Jitter/Noise PVT Model

Stratix V GX

Typical

Process: Typical/Fast/Slow Voltage:

Typical/High/Low Temperature:

–40°C to 100°C

Arria V GZ

Typical

Process: Typical/Fast/Slow Voltage:

Typical/High/Low Temperature:

–40°C to 100°C

Stratix V GT

Typical

Process: Typical/Fast/Slow Voltage:

Typical/High/Low Temperature: 0°C

to 100°C

Arria 10 GX/SX

Typical/Fast/Slow

Typical

Arria 10 GT

Typical/Fast/Slow

Typical

IBIS-AMI

Provide by IBIS-AMI

model

Provide by IBIS-AMI model

Custom

None

None

PCI-Express 8GT

None

None

JNEye to Quartus II Parameter Translation for Arria 10 GX/SX/GT Transmitters

The following table provides a translation from JNEye Arria 10 GX/SX/GT transmitter parameter names

to the equivalent Quartus II parameter names. Use the Quartus II software to transfer optimum device

settings from a JNEye simulation to an actual device configuration.

UG-1146

2015.05.04

Transmitter Setting

2-25

Functional Description

Altera Corporation

Send Feedback