Drive model numbers, Drive enclosure and revision code, Physical installation 1 - 4 – Yaskawa P7 Drive User Manual User Manual

Page 14

Advertising
background image

Physical Installation 1 - 4

Drive Model Numbers

The model number on the nameplate indicates the design specification, voltage, and rating of the Drive in alphanumeric codes.

Fig 1.2 Drive Model Number Structure

Drive Enclosure and Revision Code

The Drive SPEC number on the nameplate indicates the voltage, Drive rating, enclosure type, and the revision code of the
Drive in alphanumeric codes.

Fig 1.3 SPEC Number Structure

TERMS

Open Chassis Type (IEC IP00)
Protected so that parts of the human body cannot reach electrically charged parts from the front when the
Drive is mounted in a control panel, also called (protected chassis).

NEMA Type 1 (IEC IP20)
The Drive is shielded from the exterior, and can thus be mounted to the interior wall of a building
(not necessarily enclosed in a control panel). The protective structure conforms to the standards of NEMA
Type 1 in the USA. All protective covers (Fig 1.4) must be installed to conform with IEC IP20 and NEMA Type
1 requirements.

No.

Spec

UL Specification

CIMR – P7 U 2 0 11

AC Drive

U

No.

Voltage

2

4

3-phase, 208-240Vac

3-phase, 480Vac

Rating

P7 Family

2 011 1 A

No.

2

4

Voltage

3-phase, 208 - 240Vac

3-phase, 480Vac

No.

Enclosure Type

0

Open chassis (IEC IP00)

1

NEMA Type 1 (IEC IP20)

Hardware Revision

Rating

Advertising