Programming 5 - 56

o3 Digital Operator Copy Function

o3-01 Copy Function Selection

Note:

The copy function is disabled when serial communication is active.

o3-02 Read Allowed Selection

The digital operator has parameter COPY capabilities via built in non-volatile memory. The digital operator can READ all of
the parameters in the Drive and store them for later WRITE back to the Drive or into a Drive with the same product code and
software number. In order to read the parameter values and store them in the digital operator, select o3-02= “1: Enabled”. If
you attempt to READ the data, which overwrites any previously stored data, without first setting o3-02= “1: Enabled”, you
will get the following error:

After setting o3-02= “1: Enabled”, it is possible to store parameter values in the digital operator by setting o3-01=1 (INV

→OP

READ).

A successful READ of the parameter values will display:

An error may occur while saving the parameter values to the digital operator’s memory. If an error is displayed, press any key
to cancel the error display and return to parameter o3-01. Error displays and their meanings are covered in Chapter 6: Diag-
nostics and Troubleshooting

of the E7 Users Manual (TM.E7.01). To COPY parameter values into a Drive, set o3-01= “2: OP-

>INV WRITE”. During the writing of the parameter values into the Drive the digital operator will display:

Setting

Description

0

COPY SELECT (factory default)

1

INV

→OP READ

2

OP

→INV WRITE

3

OP

↔INV VERIFY

Setting

Description

0

Disabled (factory default)

1

Enabled

-ADV-

PRE

READ IMPOSSIBLE

-ADV-

READ

READ COMPLETE