Specifications C - 4

Table C.3 Common Drive Specifications

Model Number

CIMR-P7U

Specification

Control method

Sine wave PWM

V/f control

Speed range

40:1

Speed control accuracy

±2 to 3% (77

°F ± 50°F) (25°C ± 10°C)

Frequency accuracy
(temperature characteristics)

Digital references: ± 0.01% (14

°F to 104°F) (-10°C to +40°C)

Analog references: ±0.1% (77

°F ± 50°F) (25°C ±10°C)

Frequency setting resolution

Digital references: 0.01 Hz

Analog references: 0.025/50 Hz (10 bit with sign)

Frequency setting signal
(Speed Command)

0-10 Vdc, 4-20 mA

Acceleration/Deceleration
time

0.0 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings)

Main control functions

Restarting for momentary power loss, bi-directional speed search, overtorque detection, 5 preset speeds,

acceleration/deceleration time changes, S-curve acceleration, 3-wire sequence, auto-tuning, cooling fan ON/OFF

control, torque compensation, jump frequencies, upper and lower limits for frequency references, DC braking for

starting and stopping, high-slip braking, PI control (with sleep function), energy-saving control, Modbus communi-

cations (RS-485/422, 19.2 kbps maximum), fault reset, and copy function

Motor protection

Protection by electronic thermal overload relay

Fuse blown protection

Stops for fuse blown

Overload capacity and
maximum current

110% of rated output current for 60 seconds

Overload protection

110% of rated output current for 60 seconds

Overvoltage protection

208-240Vac: Stops when main-circuit DC voltage is above 410 V

480Vac: Stops when main-circuit DC voltage is above 820 V

Undervoltage protection

208-240Vac: Stops when main-circuit DC voltage is below 190 V

480Vac: Stops when main-circuit DC voltage is below 380 V

Momentary power loss
ridethru

Power Interruptions of 15 ms or more

By selecting the momentary power loss method, operation can be continued if power is restored within 2 s

Cooling fin overheating

Protection by thermistor

Stall prevention

Stall prevention during acceleration, deceleration, or running

Grounding protection

Protection by electronic circuits. (50% of inverter rated current)

Charge indicator

Lit when the main circuit DC voltage is approx. 50 Vdc or more

Enclosure Type

Enclosed wall-mounted type (NEMA 1): CIMR-P7U20P4 thru 2030 and 40P4 thru 4055

Open chassis type (IP00):

CIMR-P7U2022 thru 2110 and 4030 thru 4300

Ambient operating
temperature

14

°F to 104°F (-10°C to 40°C) NEMA 1 type

14

°F to 113°F (–10°C to 45°C) Open chassis type

Ambient operating humidity

95% max. (with no condensation)

Storage temperature

-4

°F to 140°F (- 20°C to + 60°C) short-term temperature during transportation

Application site

Indoor (no corrosive gas, dust, etc.)

Altitude

3300 ft. (1000 m), higher altitudes by derate

Vibration

10 to 20 Hz, 32 ft/sec

2

(9.8 m/s

2

) max.; 20 to 50 Hz, 6.5 ft/sec

2

(2 m/s

2

) max.

Approval Agency

UL File E131457