Heat Loss Data

Table 1.3 200V Class Heat Loss Data

TYPE

CIMR-P7U

Drive

(Inverter)

Capacity

(kVA)

Rated

Output

Current

(A)

Cooling

Fin Side

(W)

Internal

Unit Side

(W)

Total

Watt
Loss

(W)

Cooling

Method

20P4

1.4

3.6

19

39

58

Self

20P7

1.8

4.6

26

42

68

Self

21P5

3.0

7.8

48

50 98

Self

22P2

4.1

10.8

68

59

127

Self

23P7

6.4

16.8

110

74

184

Fan

25P5

8.8

23

164

84

248

Fan

27P5

12

31

219

113

332

Fan

2011

18

46.2

357

168

524

Fan

2015

23

59.4

416

182

597

Fan

2018

29

74.8

472

208

680

Fan

2022

34

88

583

252

835

Fan

2030

44

115

883

333

1217

Fan

2037

62

162

1010

421

1430

Fan

2045

73

192

1228

499

1727

Fan

2055

82

215

1588

619

2206

Fan

2075

120

312

1956

844

2800

Fan

2090

140

360

2194

964

3157

Fan

2110

160

415

2733

1234

3967

Fan