Diagnostic & troubleshooting 6 - 5 – Yaskawa P7 Drive User Manual User Manual

Page 149

Advertising
background image

Diagnostic & Troubleshooting 6 - 5

OC

Over Current

Overcurrent
Drive output current exceeded the
overcurrent detection level (approximately
180% of Drive rated output current)

Shorted Drive output phase to
phase, shorted motor, locked
rotor, load too heavy, accel/
decel time too short, contactor
on the Drive output is opened
and closed, a special motor or
a motor with a FLA rating
larger than Drive rated output
current

Remove the motor and run the
Drive without the motor

Check the motor for a phase-to-
phase short

Check the Drive for a phase-to-
phase short at the output

Verify C1-01 and C1-02 are set
correctly

Check load conditions

OH1

Heatsnk MAX Temp

Cooling Fin/Cooling Fin Fan Overheat
The temperature of the Drive cooling fin
exceeded the temperature programmed in
parameter L8-02

Cooling fan(s) are not
working, high ambient
temperature, a heat source is
too close to the Drive

Check for dirt build-up on the
fans and cooling fins

Reduce the ambient temperature
around the Drive

Drive Internal Cooling Fan

Remove the heating unit

OH3

Motor Overheat 1

Motor Overheating Alarm
The Drive stops or continues operation
according to the setting of L1-03.

Overheating of motor as
measured by motor thermistor

Recheck the cycle time and the
size of the load

Recheck the accel/decel time
(C1-01 and C1-02)

Recheck the V/F pattern (E1-01
thru E1-13)

Recheck the motor rated current
value (E2-01)

OH4

Motor Overheat 2

Motor Overheating Fault
The Drive stops operation according to the
setting of L1-04.

Overheating of motor as
measured by motor thermistor

Recheck the cycle time and the
size of the load

Recheck the accel/decel time
(C1-01 and C1-02)

Recheck the V/F pattern (E1-01
thru E1-13)

Recheck the motor rated current
value (E2-01)

OL1

Motor Overloaded

Motor Overload
Designed to protect the motor.
Fully adjustable from parameter E2-01

The load is too large. The
cycle time is too short at the
accel/decel time

Recheck the cycle time and the
size of the load as well as the
times set in C1-01 and C1-02

The voltage of the V/F pattern
is high

Review the V/F pattern
parameters, E1-01 thru E1-13

Motor rated current setting is
improper

Check the motor rated current
value in E2-01

OL2

Inv Overloaded

Drive Overload
Designed to protect the Drive

The load is too large. The
cycle time is too short at the
accel/decel time

Recheck the cycle time and the
size of the load as well as the
times set in C1-01 and C1-02

The voltage of the V/F pattern
is high

Review the V/F pattern
parameters, E1-01 thru E1-13

The size of the Drive is small

Change to a larger size Drive

OL3

Overtorque Det 1

Overtorque Detection 1
Drive output current > L6-02 for more than
the time set in L6-03

Motor is overloaded

Ensure the values in L6-02 and
L6-03 are appropriate

Check application/machine
status to eliminate fault

Table 6.1 Fault Displays and Processing

Digital

Operator Display

Description

Cause

Corrective Action

Advertising