Quick setting menu (-quick-), Quick setting menu (-quick-) -11, Digital operator 3 - 11 – Yaskawa P7 Drive User Manual User Manual

Page 69

Advertising
background image

Digital Operator 3 - 11

Quick Setting Menu (-QUICK-)

This menu is used to set/read the most commonly used parameters in the Drive. Follow the key operations below (Fig. 3.6) to
access the Quick Setting Menu:

Fig 3.6 Quick Setting Parameter Access Procedure

Use

and

keys to scroll through the “Quick Setting” parameter list.

Table 3.11 Quick Setting Parameter List

Parameter

Number

Parameter Name

Parameter

Number

Parameter Name

A1-00

Language Selection

b5-29

PI Square Root Gain

b1-01

Frequency Reference Selection

b5-30

Output Square Root Monitor Selection

b1-02

Run command Selection

b8-01

Energy Savings Control Selection

b1-03

Stopping Method Selection

C1-01

Acceleration Time 1

b1-04

Reverse Operation Selection

C1-02

Deceleration Time 1

b4-01

Delay-On Timer

b5-01

PI Mode Selection

d2-01

Frequency Reference Upper Limit

b5-02

Proportional Gain Setting

d2-02

Frequency Reference Lower Limit

b5-03

Integral Time Setting

E1-01

Input Voltage Setting

b5-04

Integral Limit Setting

E2-01

Motor Rated Current

b5-06

PI Output Limit

F6-01

Operation Selection After Communication Error

b5-07

PI Offset Adjustment

H3-02

Terminal A1 Gain Setting

b5-08

PI Primary Delay Time

H3-03

Terminal A1 Bias Setting

b5-09

PI Output Level Selection

H3-10

Terminal A2 Gain Setting

b5-10

PI Output Gain Setting

H3-11

Terminal A2 Bias Setting

b5-11

PI Output Reverse Selection

L2-01

Momentary Power Loss Detection Selection

b5-12

PI Feedback Reference Missing Detection Selection

L2-02

Momentary Power Loss Ride-thru Time

b5-13

PI Feedback Loss Detection Level

L4-05

Frequency Reference Loss Detection Selection

b5-14

PI Feedback Loss Detection Time

L4-06

Frequency Reference Level at Loss Frequency

b5-15

PI Sleep Function Start Level

L5-01

Number of Auto Restarts Attempts

b5-16

PI Sleep Delay Time

L5-03

Maximum Restart Time After Fault

b5-17

PI Accel/Decel Time

L6-01

Torque Detection Selection 1

b5-18

PI Setpoint Selection

L6-02

Torque Detection Level 1

b5-19

PI Setpoint Value

L6-03

Torque Detection Time 1

b5-20

PI Setpoint Display Setting

L8-11

Heatsink Cooling Fan Operation Delay Time

b5-21

PI Sleep Input Source

o1-01

User Monitor Selection

b5-22

PI Snooze Level

o1-05

LCD Brightness Adjustment

b5-23

PI Snooze Delay Time

o1-07

Second Line User Monitor Selection

b5-24

PI Snooze Deactivation Level

o1-08

Third Line User Monitor Selection

b5-25

PI Setpoint Boost Setting

o2-03

User Parameter Default Value

b5-26

PI Maximum Boost Time

o2-05

Frequency Operation Time Selection

b5-27

PI Snooze Feedback Level

o2-08

Cumulative Operation Time Selection

b5-28

PI Feedback Square Root Ac Function Selection

o3-02

Read Allowed Selection

-QUICK-

** Main Menu **

- - - - - - - - - - - - - -

Quick Setting

-QUICK-

Reference Source

- - - - - - - - - - - - - - - - - - - -

B1-01= 1

*1*

Terminals

“1”

x2

Advertising