Parameters A - 16

Table 1: Parameter List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Menu

Location

Analog Inputs

H3-02

Terminal A1 Gain Setting
Terminal A1 Gain

Sets the speed command when 10V is input, as a
percentage of the maximum output frequency (E1-04).

0.0 to

1000.0

100.0%

Programming

H3-03

Terminal A1 Bias Setting
Terminal A1 Bias

Sets the speed command when 0V is input, as a
percentage of the maximum output frequency (E1-04).

–100.0 to

+100.0

0.0%

Programming

H3-08

Terminal A2 Signal Level
Selection
Term A2 Signal

Selects the signal level of terminal A2.
0: 0 - 10VDC (switch S1-2 must be in the off position)
2: 4 - 20 mA (switch S1-2 must be in the on position)

0 or 2

2

Programming*

H3-09

Aux Terminal Function Selection
Terminal A2 Sel

Selects what effect the Aux terminal (A2) has on the
drive.
0: Frequency Bias - 0 - 100% bias
2: Aux Reference
B: PI Feedback
D: Frequency Bias 2 - 0 - 100% bias
E: Motor Temperature - See parameters L1-03 & L1-04
16: PI Differential
1F: Not Used

0 to 1F

2**

Programming*

H3-10

Terminal A2 Gain Setting
Terminal A2 Gain

Sets the level of the A2 function corresponding to a
10V input (in%).

0.0 to

1000.0

100.0%

Programming

H3-11

Terminal A2 Bias Setting
Terminal A2 Bias

Sets the level of the A2 function corresponding to a
0V input (in%).

–100.0 to

+100.0

0.0%

Programming

H3-12

Analog Input Filter Time Constant
Filter Avg Time

Used to “smooth” out erratic or noisy analog input
signals.

0.00 to

2.00

0.30sec

Programming

H3-13

Master Frequency Reference
Terminal Selection
TA1/A2 Select

Determines which terminal will be the main reference
source.
0: Main Fref TA1 - Terminal TA1 is the main speed

command and Terminal TA2 is the Aux speed

command.
1: Main Fref TA2 - Terminal TA2 is the main speed

command and Terminal TA1 is the Aux speed
command.

Only effective when H3-09 is set to 2 “Aux Refer-

ence.”

0 or 1

0

Programming*