Digital Operator 3 - 14

Example of Changing a Parameter

Table 3.14 provides an example of how to change parameter “C1-02” (Deceleration Time 1) from 30 seconds to 40 seconds.

Table 3.14 Changing a Parameter in the Programming Menu

Step

Number

Digital Operator Display

Description

1

The Drive is first powered up.

2

Press the MENU key to scroll to “Operation” menu.

3

Press the MENU key to scroll to “Quick Setting” menu.

4

Press the MENU key to scroll to “Programming” menu.

5

Press the DATA/ENTER key to enter “Programming” menu.

6

Press the INCREASE key until C1-01 (Accel/Decel) is displayed.

7

Press the SHIFT/RESET key to move flashing digit to the right.

-DRIVE- Rdy

Frequency Ref

U1-

01

= 0.00Hz

- - - - - - - - - - - - - - - - - - - -

U1-02= 0.00Hz

U1-03= 0.00A

-DRIVE-

** Main Menu **

- - - - - - - - - - - - - -

Operation

-QUICK-

** Main Menu **

- - - - - - - - - - - - - -

Quick Setting

-ADV-

** Main Menu **

- - - - - - - - - - - - - -

Programming

-ADV-

Initialization

- - - - - - - - - - - - - - - - - - - -

A1

-01= 0

Select Language

-ADV-

Accel/Decel

- - - - - - - - - - - - - - - - - - - -

C1

-01= 1.0sec

Accel Time 1

-ADV-

Accel Time 1

- - - - - - - - - - - - - - - - - - - -

C1-

01

= 30.0sec

(0.0~6000.0)

“30.0sec”