Preventive maintenance, Preventative maintenance -3, Maintenance 7 - 3 – Yaskawa P7 Drive User Manual User Manual

Page 171

Advertising
background image

Maintenance 7 - 3

Preventive Maintenance

If the Drive is used under the following conditions, it may be necessary to inspect more often:

High ambient temperatures, humidity or altitudes above 3,300 feet

Frequent starting and stopping

Fluctuations of the AC power supply or load

Excessive vibration and/or shock loading

Poor environment, including dust, metal particles, salt, sulfuric acid, chlorine

Table 7.3 Preventive Maintenance

Inspection Points

Item

Check Points

Every 3-6 Months

Yearly

General

Environment

Ambient Temperature

Humidity

Dust

Harmful Gas

Oil Mist

X

X

X

X

X

Equipment

Abnormal vibration or noise

X

AC Power Supply

Main circuit & control voltage

X

AC Power Circuit &

Devices

Conductors & Wire

Connections

Loose lugs, screws & wires

Hot spots on parts

Corrosion

Bent conductors

Breakage, cracking or discoloration

Check spacing

X

X

X

X

X

X

Transformers & Reactors

Discoloration or Noise

X

Terminal Blocks

Loose, damaged

X

DC Bus Capacitors

Leakage

Ruptures, broken, expansion

Capacitance & insulation resistance

X

X

X

Relays & Contactors

Noisy

Contact discoloration

X

X

Soft Charge Resistors

Cracked

Discoloration

X

X

Control Circuits

Operation

Speed reference voltage/current

I/O contact operation

X

X

Cooling System

Cooling Fans/Fins & Heatsink

Abnormal fan noise

Loose connectors

Free of accumulation

X

X

X

Keypad/Display

Digital Operator

LEDs

Monitor display values

Key functionality

Clean

X

X

X

X