5.2 Command Related Parameters Details

5-21

5

Command Related Parameters

5.2.7 STATUS Field and Monitor Related Settings

(1) STATUS Field Status Detection Level Setting

This section describes the parameters for setting the status detection levels for the STATUS field data.

„

Origin (ZPOINT) Range Setting

Set the ZPOINT signal status detection range.

Note: ZPOINT detection will be performed only after completion of the following operations. Otherwise, it will not be

performed.

• When an incremental encoder is connected

• Homing operation by ZRET command is completed.
• The coordinate setting is completed after reference point setting (REFE = 1) by executing POS_SET com-

mand.

• When an absolute encoder is connected

• Execution of SENS_ON command is completed.

„

Positioning Completed (PSET) Width Setting

Set the PSET signal status detection range.

Note: PSET = 1 when output is completed (DEN = 1) and the feedback position (APOS) is within the positioning com-

pleted (PSET) detection range.

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn803

Origin Range

2

0 to 250

Reference unit

10

Feedback position
(APOS)

Origin Range

(Pn803)

ZPOINT detection range

Origin(0)

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn522

Positioning Completed Width

4

0 to 1073741824

Reference unit

7

Feedback position
㧔APOS㧕

Positioning Completed Width
(Pn522)

PSET detection

range

Target position
(TPOS)