2 commands details, 1 no operation (nop: 00h), 2 commands details -3 – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 34: 1 no operation (nop: 00h) -3, 1) nop command (00h), 2) alarm

Advertising
background image

3.2 Commands Details

3-3

3

C

o

mm

an

ds

f

or

P

reparation

P

roce

ss

3.2 Commands Details

3.2.1 No Operation (NOP: 00H)

After turning on the control and main circuit power supplies, send NOP command to check if initialization of
SERVOPACK has been completed or not.

(1) NOP Command (00H)

The specifications of the NOP command are shown below.

(2) ALARM

The uppermost two digits of the SERVOPACK alarm code are set in the ALARM field of the response.

For example, ALARM = 02 when a parameter checksum error 1 (A.020) occurs.

If no alarm occurs, ALARM = 00.
For details on alarms and alarm codes, refer to the applicable manual for design and maintenance of the SER-
VOPACK.

Byte

NOP

Description

Command

Response

1

00H

00H

Phases in

which the

command can

be executed

All phases

Synchronization

classification

Asynchronous
command

2

ALARM

Processing

time

Within commu-

nications cycle

Subcommand

Can be used.

3

STATUS

• Returns the ALM, WARNG, and CMDRDY bits in STATUS field.

Other bits will not be specified.

• The response will be NOP from the moment the power is turned on until

the initialization of SERVOPACK is completed. During this time,
CMDRY = 0.

4

5

6

7

8

9

10

11

12

13

14

15

16

WDT

RWDT

17

Subcommand

area

Subcommand

area

18

19

20

21

22

23

24

25

26

27

28

29