1 mechatrolink-ii subcommands list, 2 mechatrolink-ii subcommands details, 1 no operation (nop: 00h) – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 115: 1 mechatrolink, 2 mechatrolink, 1 no operation (nop: 00h) -2, 1 mechatrolink-ii subcommands list -2, 2 mechatrolink-ii subcommands details -2, 1) substatus field specification

Advertising
background image

6 MECHATROLINK-II Subcommands

6.2.1 No Operation (NOP: 00H)

6-2

6.1 MECHATROLINK-II Subcommands List

The MECHATROLINK-II subcommands can be used by specifying them with the CONNECT command

when MECHATROLINK-II communications starts.

The specifications of each MECHATROLINK-II subcommand are described below.

Refer to 1.2.3 Combination of MECHATROLINK-II Main Commands and Subcommands for information on
applicable combinations with main commands.

6.2 MECHATROLINK-II Subcommands Details

6.2.1 No Operation (NOP: 00H)

(1) Substatus Field Specification

This substatus field is used to monitor status of subcommands.

• Substatus Field

Byte

NOP

Description

Command

Response

17

00H

00H

• Not operation command

18

SUBSTATUS

19

20

21

22

23

24

25

26

27

28

29

Byte

18

D7

D6

D5

D4

D3

D2

D1

D0

Reserved

Reserved

Reserved

Reserved

Reserved

SBCM-

DRDY

SBWARNG

SBALM

Bit

Name

Description

Value

Status

D0

SBALM

Subcommand alarm occurs.

0

No alarm

1

Alarm occurs

D1

SBWARNG

Subcommand warning occurs.

0

No warning

1

Warning

D2

SBCMDRDY

Subcommand Ready

(Subcommand can be received)

0

Busy

1

Ready