18 (2) operation, 3) related parameters – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 83

Advertising
background image

4 Motion Commands for Operation

4.2.8 External Input Positioning (EX_POSING: 39H)

4-18

(2) Operation

The operation executed by EX_POSING command is illustrated below.

(3) Related Parameters

The parameters related to the execution of EX_POSING command are listed below.

Parameter number in parentheses is when Pn833 = 1.

Set the parameters as shown below to use TLIM.

When the latch signal is input
Positioning to the position: Latch signal input position LPOS + Final
Travel Distance for External Positioning (Pn814)

When the latch signal is not input
Positioning to the specified target position TPOS

Latch signal

Parameter No.

Name

Parameter No.

Name

Pn80A (Pn834)

1st Linear Acceleration Con-
stant

Pn80F (Pn83E)

Deceleration Constant Switching Speed

Pn80B (Pn836)

2nd Linear Acceleration Con-
stant

Pn814

Final Travel Distance for External Positioning

Pn80C (Pn838)

Acceleration Constant
Switching Speed

Pn820

Forward Latching Allowable Area

Pn80D (Pn83A)

1st Linear Deceleration Con-
stant

Pn822

Reverse Latching Allowable Area

Pn80E (Pn83C)

2nd Linear Deceleration Con-

stant

Pn81F

Position Control Command TLIM Function Allo-
cation

Pn002

Torque (Force) Reference Option during Speed/
Position Control

Parameter

No.

Set Value

Meaning

Pn81F

n.††1†

Enables positive/negative torque (force) limit (TLIM).

Pn002

n.†††1

Pn81F

n.††1†

When P_CL of OPTION field is set to 1: Uses TLIM as positive torque (force) limit.
When N_CL of OPTION field is set to 1: Uses TLIM as negative torque (force) limit.

Pn002

n.†††3

Advertising