24 (2) speed limit option 1, 3) speed limit option 2 – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 89

Advertising
background image

4 Motion Commands for Operation

4.2.11 Torque (Force) Control (TRQCTRL: 3DH)

4-24

(2) Speed Limit Option 1

„

When Using a Rotational Servomotor

Use Pn407 (Speed Limit during Torque Control) to set the speed limit.

Note: If a speed higher than the maximum speed of the connected servomotor is set, the servomotor speed will be limited

to its maximum speed.

„

When Using a Linear Servomotor

Use Pn480 (Speed Limit during Force Control) to set the speed limit.

Note: If a speed higher than the maximum speed of the connected linear servomotor is set, the linear servomotor speed will

be limited to its maximum speed.

(3) Speed Limit Option 2

Set the following parameter to enable VLIM (Speed Limit) specified in TRQCTRL command.

Pn407

Speed Limit during Torque Control

Setting Range

Unit

Factory Setting

When Enabled

0 to 10000

1 min

-1

10000

Immediately

Pn480

Speed Limit during Force Control

Setting Range

Unit

Factory Setting

When Enabled

0 to 5000

mm/s

5000

Immediately

Parameter

Description

Pn002

n.††0†

Disables VLIM. (factory setting)

n.††1†

Enables VLIM (Uses VLIM as the speed limit.)

Advertising