(4) Details WDT and RWDT
The watchdog timer data will be set in WDT and RWDT of NOP command and response as shown below.
The watchdog timer is checked after synchronous communications has been established.
The SERVOPACK watchdog timer data will be refreshed whether synchronous communications is established
or not.
D13
N_SOT
0
OT signal is OFF.
1
OT signal is ON.
D14
–
–
–
D15
–
–
–
Bit
Name
Value
Description
D7
D4 D3
D0
WDT
SN: Copy of RSN in RWDT
MN: Incremented by 1 each
communications cycle
MN: Master station watchdog timer count
D7
D4 D3
D0
RWDT RSN: Incremented by 1 each
communications cycle
RMN: Copy of MIN in WDT
RSN: SERVOPACK’s watchdog timer count