3 release latch mode (ltmod_off: 29h), 3 release latch mode (ltmod_off: 29h) -8, 1) ltmod_off command (29h) – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 73

Advertising
background image

4 Motion Commands for Operation

4.2.3 Release Latch Mode (LTMOD_OFF: 29H)

4-8

4.2.3 Release Latch Mode (LTMOD_OFF: 29H)

(1) LTMOD_OFF Command (29H)

The LTMOD_OFF command is used to release the latch mode.

Byte

LTMOD_OFF

Description

Command

Response

1

29H

29H

Phases in

which the

command can

be executed

Phase 2 and 3

Synchronization

classification

Asynchronous
command

2

ALARM

Processing

time

Within commu-
nications cycle

Subcommand

Can be used

3

STATUS

• Check that CMDRDY is 1 to confirm that this command has been

received.

• It takes 250

μs max. to release the latch mode.

• This command cannot be used while LATCH, ZRET, EX_POSING, or

SVCTRL command is being executed.

If used, the command warning 4 (A.95D) will occur.

4

5

MONITOR1

6

7

8

9

MONITOR2

10

11

12

13

SEL_MON1/2 SEL_MON1/2

14

IO_MON

15

16

WDT

RWDT

17

Subcommand

area

Subcommand

area

18

19

20

21

22

23

24

25

26

27

28

29

Advertising