4 Motion Commands for Operation

4.2.2 Set Latch Mode (LTMOD_ON: 28H)

4-6

(3) Continuous Latch Mode

This function sequentially latches the input positions of sequence signal 1 to sequence signal n (n = 1 to 8) for

a specified number of times. The continuous latch operation can be aborted by executing the LTMOD_OFF
command. This function can shorten the time between latch completion and the start of the next latch, and

enables sequential latch operations at high speed.

„

How to Start and Stop Continuous Latch Operation

Set the following parameters, and then set LT_MOD to 1 to execute the LTMOD_ON command. The continu-

ous latch operation will start. To abort the operation, execute the LTMOD_OFF command.

Pn850: Latch Sequence Number n

Pn851: Continuous Latch Count m (When m = 0, the continuous latch operation will be infinitely repeated.)

Pn852: Latch Sequence Signal 1 to 4 Setting

Pn853: Larch Sequence Signal 5 to 8 Setting

Note: If the LTMOD_ON command is executed by setting Pn850 to 0 and LT_MOD to 1, the latch mode error warning

(A.94E) will occur and the latch operation will not start.

„

Latch Status

Latch completion can be confirmed by the following status.

[STATUS Field: The 3rd and 4th byte]

L_CMP (D10): L_CMP is set to 1 for one communications cycle every time the external signal is input.

[EX_STATUS Field: The 28th and 29th byte]

L_SEQ_NO (D8-D11): The latch sequence signal number (value n) at latch completion

L_CMP_CNT (D0-D7): The continuous latch count (value m)

(Added at completion of position latch when the latch sequence signal n is

input.)

Note: LPOS is forcibly output to MONITOR 2 for one communications cycle while L_CMP = 1 every time the external

signal is input.

Latches the sequence signal 1 input position.

Latches the sequence signal 2 input position.

Repeats m times

Latches the sequence signal n input position.

..

Note 1: N, the number of sequence signals,

is specified by Pn850.

2: The signals for sequence signal n

are selected by Pn852 and Pn853.

3: The number of times of continuous

latching m is set by Pn851.