5 Command Related Parameters

5.2.7 STATUS Field and Monitor Related Settings

5-22

„

NEAR Signal Width Setting

Set the NEAR signal status detection range.

Note: NEAR = 1 when the feedback position (APOS) is within the NEAR signal detection range.

„

Zero-speed (ZSPD) Detection Level Setting

Set the ZSPD signal status detection level during speed control (VELCTRL command).

„

Speed Coincidence (VCMP) Detection Level Setting

Set the VCMP signal status detection level during speed control (VELCTRL command).

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn524

NEAR Signal Width

4

0 to 1073741824

Reference unit

7

Feedback position
(APOS)

NEAR Signal Width
(Pn524)

NEAR detection

range

Target position
(TPOS)

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn502

Rotation Detection Level

(For rotational servomotors)

2

1 to 10000

min

-1

20

Pn581

Travel Detection Level

(For linear servomotors)

2

1 to 5000

mm/s

20

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn503

Speed Coincidence Signal Output Width

(For rotational servomotors)

2

0 to 100

min

-1

10

Pn582

Speed Coincidence Signal Output Width

(For linear servomotors)

2

0 to 100

mm/s

10