13 read parameters (prm_rd: 01h), 13 read parameters (prm_rd: 01h) -25, 1) prm_rd command (01h) – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 56

Advertising
background image

3.2 Commands Details

3-25

3

Commands for Preparation Process

3.2.13 Read Parameters (PRM_RD: 01H)

Send a PRM_RD command to read out parameters.

(1) PRM_RD Command (01H)

The specifications of the PRM_RD command are described below.

Byte

PRM_RD

Description

Command

Response

1

01H

01H

Phases in

which the

command can

be executed

Phase 2 and 3

Synchronization

classification

Asynchronous

command

2

ALARM

Processing

time

Within 200 ms

Subcommand

Can be used

3

STATUS

• Reads out parameters.
• A warning will occur and the command will be ignored in the following

cases.
- NO is out of the range: Data setting warning 1 (A.94A)
- SIZE does not match: Data setting warning 4 (A.94D)

4

5

NO

NO

6

7

SIZE

SIZE

8

PARAMETER

9

10

11

12

13

14

15

16

WDT

RWDT