background image

4 Motion Commands for Operation

4.2.5 Positioning (POSING: 35H)

4-12

Positioning will be performed as illustrated below.

(2) Related Parameters

The parameters related to the execution of POSING command are listed below.

Parameter number in parentheses is when Pn833=1.

Set the parameters as shown below to use TLIM.

Command speed

Acceleration

constant

switching

speed

1st linear acceleration constant

2nd linear

acceleration constant

1st linear deceleration constant

TSPD

Time

2nd linear deceleration constant

Deceleration constant

switching speed

Parameter No.

Name

Pn80A (Pn834)

1st Linear Acceleration Constant

Pn80B (Pn836)

2nd Linear Acceleration Constant

Pn80C (Pn838)

Acceleration Constant Switching Speed

Pn80D (Pn83A)

1st Linear Deceleration Constant

Pn80E (Pn83C)

2nd Linear Deceleration Constant

Pn80F (Pn83E)

Deceleration Constant Switching Speed

Pn81F

Position Control Command TFF/TLIM Function Allocation

Pn002

Torque (Force) Reference Option During Speed/Position
Control

Parameter

No.

Set Value

Meaning

Pn81F

n.††1†

Enables forward/reverse torque (force) limit using TLIM.

Pn002

n.†††1

Pn81F

n.††1†

When P_CL of OPTION field is set to 1: Uses TLIM as positive torque (force) limit.
When N_CL of OPTION field is set to 1: Uses TLIM as negative torque (force) limit

Pn002

n.†††3