1) linear acceleration/deceleration function, 1) linear acceleration/deceleration function -6 – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 95

Advertising
background image

5 Command Related Parameters

5.2.2 Motion Acceleration/Deceleration Function Setting

5-6

5.2.2 Motion Acceleration/Deceleration Function Setting

This section describes the parameters used to set the acceleration/deceleration function for motion commands

for positioning.

(1) Linear Acceleration/Deceleration Function

Use the following parameters to set the acceleration/deceleration constants used to execute POSING, FEED,
EX_POSING, ZRET, or HOLD commands.

The 1st digit of Pn833 is used to switch the parameters used for acceleration/deceleration: the parameters
Pn80A to Pn80F and Pn827 or the parameters Pn834 to Pn840.

„

Acceleration/Deceleration Constant Switching Setting

Note: The setting will be validated by turning the power supply OFF and then ON again, or by executing the CONFIG

command.

„

Acceleration/Deceleration Parameters when Pn833=n.†††0

Command speed

Acceleration constant
switching speed

1st linear acceleration constant

1st linear deceleration constant

TSPD

Time

Deceleration constant switching speed

2nd linear
acceleration constant

2nd linear deceleration
constant

Parameter

Meaning

Factory

Setting

Pn833

n.†††0

Use parameters Pn80A to Pn80F and Pn827.
(Parameters Pn834 to Pn840 are invalid.)

n.†††0

n.†††1

Use parameters Pn834 to Pn840.
(Parameters Pn80A to Pn80F and Pn827 are invalid.)

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn80A

1st Linear Acceleration Constant 1

2

1 to 65535

10000

reference units/s

2

100

Pn80B

2nd Linear Acceleration Constant 1

2

1 to 65535

10000

reference units/s

2

100

Pn80C

Acceleration Constant Switching Speed 1

2

0 to 65535

100

reference units/s

0

Pn80D

1st Linear Deceleration Constant 1

2

1 to 65535

10000

reference units/s

2

100

Pn80E

2nd Linear Deceleration Constant 1

2

1 to 65535

10000

reference units/s

2

100

Pn80F

Deceleration Constant Switching Speed 1

2

0 to 65535

100

reference units/s

0

Pn827

Linear Deceleration Constant 1 for Stopping

2

0 to 65535

10000

reference units/s

2

100

Advertising