10 turn servo on (sv_on: 31h), 10 turn servo on (sv_on: 31h) -20, 1) sv_on command (31h) – Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 51

Advertising
background image

3 Commands for Preparation Process

3.2.10 Turn Servo ON (SV_ON: 31H)

3-20

3.2.10 Turn Servo ON (SV_ON: 31H)

Send the SV_ON command to power the servomotor and make it ready for operation.

(1) SV_ON Command (31H)

The specifications of the SV_ON command are described below.

∗ The HWBB function cannot be used with DC power input Σ-V series SERVOPACKs (SGDV-†††E11).

Byte

SV_ON

Description

Command

Response

1

31H

31H

Phases in

which the

command can

be executed

Phase 2 and 3

Synchronization

classification

Asynchronous

command

2

ALARM

Processing

time

Normally 50 ms
(10 s max.)

Subcommand

Can be used

3

OPTION

STATUS

• Powers the servomotor and makes it ready for operation.
• Command warning 1 (A.95A) will occur and the command will be

ignored if the command is sent:
- During alarm occurrence (When ALM of STATUS is 1)
- When the main power supply is OFF (PON of STATUS is 0)
- When the HWBB signal is ON (HWBB of IO_MON is 1)

*

- Before completion of execution of SENS_ON when an absolute

encoder is used

• OPTION field can be selected
• Upon completion of execution of this command, the reference position

(POS) must be read, and the controller coordinate system must be set up.

4

5

MONITOR1

6

7

8

9

MONITOR2

10

11

12

13

SEL_MON1/2 SEL_MON1/2

14

IO_MON

15

16

WDT

RWDT

17

Subcommand

area

Subcommand

area

18

19

20

21

22

23

24

25

26

27

28

29

Advertising