5 Command Related Parameters

5.2.3 Motion Sequence Setting

5-10

5.2.3 Motion Sequence Setting

This section describes parameters related to the actions of EX_POSING and ZRET commands.

(1) Settings for EX_POSING Command

Set the travel distance from the external signal input position to the final target position for execution of an

EX_POSING command. If a negative value (distance to the negative direction) or a small value is set, the axis
will decelerate to a stop and then move to the reverse direction for positioning.

(2) Settings for ZRET Command

This section describes the parameters to set the following items for ZRET command.

• Pn816: Homing direction selection
• Pn817 or Pn842: Approach speed after the origin limit signal is input (DEC signal turns ON)
• Pn818 or Pn844: Approach (creep) speed after the latch signal is input
• Pn819: Final travel distance from the latch signal input position to the origin

∗1. The value of Pn842 is effective only when the value of Pn817 is 0.

∗2. The value of Pn844 is effective only when the value of Pn818 is 0.

Information: Set Pn819 (Final Travel Distance for Homing) to a value that satisfies the following

equation.

When Pn816=n.†††0: Origin = Latch signal input position + Pn819

When Pn816=n.†††1: Origin = Latch signal input position – Pn819

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn814

Final Travel Distance for External Position-
ing

4

–1073741823 to

1073741823

Reference unit

100

Final Travel Distance for External Positioning (Pn814)

Latch signal

Parameter

Meaning

Factory Setting

Pn816

n.†††0

Forward direction homing

n.†††0

n.†††1

Reverse direction homing

Parameter

No.

Name

Data

Size

(byte)

Setting Range

Unit

Factory

Setting

Pn817

Homing Approach Speed 1

*1

2

0 to 65535

100

reference units/s

50

Pn842

4

0 to 20971520

0

Pn818

Homing Approach Speed 2

*2

2

0 to 65535

100

reference units/s

5

Pn844

4

0 to 20971520

0

Pn819

Final Travel Distance for Homing

4

–1073741823 to

1073741823

Reference unit

100

Latch signal

Final Travel Distance for Homing (Pn819)

DEC

TSPD

Homing Approach Speed 1 (Pn817 or Pn842)

Homing Approach Speed 2 (Pn818 or Pn844)