6 MECHATROLINK-II Subcommands

6.2.4 Read Alarm or Warning (ALM_RD: 05H)

6-4

6.2.4 Read Alarm or Warning (ALM_RD: 05H)

6.2.5 Write Non-volatile Parameter (PPRM_WR: 1CH)

Byte

ALM_RD

Description

Command

Response

17

05H

05H

• Reads the alarm or warning.

This command has the same function as the main command
ALM_RD.

• When ALM_RD_MOD is set to 2 or 3, an alarm index will be

assigned to byte 20 in the command and the response. An alarm code
is assigned to both byte 21 and byte 22 in the response.

18

SUBSTATUS

19

ALM_RD_MOD ALM_RD_MOD

20

ALM_DATA

21

22

23

24

25

26

27

28

29

Byte

PPRM_WR

Description

Command

Response

17

1CH

1CH

• Writes the parameters.

This command has the same function as the main command
PPRM_WR.

18

SUBSTATUS

19

NO

NO

20

21

SIZE

SIZE

22

PARAMETER

PARAMETER

23

24

25

26

27

28

29